Kratos Automations provides a complete range of Pollution Control Equipment designed to ensure clean, safe, and compliant working environments. Our systems are engineered to handle dust, fumes, VOCs, and process emissions commonly generated in coating, blasting, grinding, and thermal applications.
Each solution is built with high-efficiency filtration, low maintenance requirements, and long service life — ensuring stable performance in demanding industrial conditions.
Our industrial dust collectors effectively capture airborne particulate generated during blasting, coating, sanding, and material handling operations.
| Parameter | Specification |
|---|---|
| Dust Collector Type | Cartridge Type / Bag Filter Type |
| Application | Shot blasting, coating booth overspray, polishing applications |
| Airflow Capacity | As per system requirement (CFM / m³/hr) |
| Filtration Efficiency | ≥ 90% for particles ≥ 5 microns |
| Filter Media | Polyester / PTFE-coated cartridges or filter bags antistatic |
| Number of Filters | As per airflow requirement and dust load |
| Cleaning Mechanism | Automatic pulse-jet cleaning |
| Dust Collection Hopper | MS fabricated hopper with flanged outlet |
| Dust Discharge System | Manual discharge |
| Exhaust Fan Type | Backward-curved centrifugal blower |
| Motor Power | As per airflow and system static pressure |
| Control System | Electrical control panel with auto / manual cleaning cycle |
| Noise Level | ≤ 80 dB at 1 m distance |
| Construction | MS fabricated structure with powder-coated finish |
| Safety Features | Differential pressure monitoring, access door interlocks |
| Compliance | Designed as per industrial ventilation and safety standards |
Designed for coating lines, ovens, spraying operations, and VOC removal — our fume extractors keep working environments clean and compliant.
| Parameter | Specification |
|---|---|
| Fume Extractor Type | Portable / Centralized Fume Extraction System |
| Application | Furnace fumes, oven fumes, paint fumes |
| Extraction Method | Source capture via hood / flexible extraction arm |
| Airflow Capacity | As per application requirement (CFM / m³/hr) |
| Fume Extraction Arm | Flexible extraction arm with adjustable hood (2 m / 3 m length) |
| Exhaust Fan Type | Backward-curved centrifugal blower |
| Motor Power | As per airflow and system static pressure |
| Noise Level | ≤ 80 dB at 1 m distance |
| Dust / Fume Treatment | Connected to wet or dry type scrubber |
| Control System | Electrical control panel with ON/OFF control |
| Construction | MS / SS fabricated structure with powder-coated finish |
| Mobility | Fixed type / Portable type with caster wheels |
| Compliance | Designed as per industrial ventilation and safety standards |
Wet and dry scrubber systems engineered for absorbing gases, odors, chemicals, and particulate — designed to meet environmental compliance across high-emission applications.
| Parameter | Specification |
|---|---|
| Scrubber Type | Wet Scrubber / Dry Scrubber |
| Application | Furnace fumes, oven exhaust, paint fumes, chemical vapors |
| Gas Handling Capacity | As per process requirement (CFM / m³/hr) |
| Removal Efficiency | Up to 90-99% (depending on pollutant type) |
| Scrubbing Medium | Water / Chemical solution (as per application) |
| Construction Material | FRP / PP / SS / MS (process dependent) |
| Mist Eliminator | Multi-layer vane type / mesh type |
| Circulation Pump | Centrifugal pump with corrosion-resistant wetted parts |
| Make-up Water System | Automatic make-up with level control |
| Blow down System | Manual / Automatic |
| Exhaust Fan Type | Backward-curved centrifugal blower |
| Control System | Electrical control panel with pump, fan, and level controls |
| Noise Level | ≤ 80 dB at 1 m distance |
| Safety Features | Low-level cut-off, overflow protection, access doors |
| Compliance | Designed as per industrial emission and safety standards |
High-performance AHUs designed for controlled airflow, temperature, and humidity — essential for paint booths and clean manufacturing areas.
| Parameter | Specification |
|---|---|
| AHU Type | Portable / Centralized AHU System |
| Application | Paint booths, clean manufacturing areas, coating lines |
| Airflow Capacity | As per application requirement (CFM / m³/hr) |
| External Static Pressure | As per ducting and system layout |
| Blower Type | Backward-curved centrifugal blower |
| Motor Type | As per airflow and system static pressure |
| Motor Power | As per airflow and system static pressure |
| Filtration Stages | Pre-filter + Fine filter (EU3 / EU5 or equivalent) |
| Heating System | Electric / Hot water coil (as per application) |
| Cooling System | Chilled water coil / DX coil (as per application) |
| Air Distribution | MS / SS fabricated ducting with powder-coated finish |
| Casing Construction | Double-skin insulated panels with powder-coated finish |
| Insulation | High-density PUF / mineral wool |
| Noise Level | ≤ 80 dB at 1 m distance |
| Control & HMI System | PLC-based control with HMI for airflow, temperature and alarm monitoring |
| Safety Features | Motor overload protection, filter clog indication |
| Compliance | Designed as per industrial ventilation and safety standards |